| PID lamp |
10.6eV (Krypton)
|
| Detection range |
Standard: 0.0-100.0ppm (resolution: 0.1ppm)
Optional: 0.00-20.00ppm (resolution: 0.01ppm)
Optional: 0-1000ppm (resolution: 1ppm)
|
| Accuracy |
Range 0.0-100.0ppm: ±2% F.S.
Range 0.00-20.00ppm: ±2% F.S
Range 0-1000ppm: ±5% F.S.
|
| Response time |
T90 < 20s (Isobutene)
|
| Linearity |
0-100ppm: >98%
|
| Power supply |
DC9V to DC36V (Max current 125mA @DC24V)
|
| Display |
LCD screen (200×140 pixel with backlight)
LED indications for normal, alarm and fault
|
| Alarming signal |
Audible and visual
|
| Ex grade |
Ex d IIC T6 Gb / Ex tD A21 IP66 80°C
|
| Ingress protection |
IP66
|
| Working temp. |
-40°C -55°C
|
| Related humidity |
0 – 98% (no condensation)
|
| Signal output |
4-20mA analog signal
MODBUS RS485
3 dry relays (capacity DC30V/3A)
|
| Dimension |
134mm×125mm×125mm (5.25”×4.90”×4.90”)
|
| Weight |
About 3.5kg
|
| Operation |
By magnetic rod / IR remote controller
|
| Calibration |
Zero point = activated carbon canister
|
| span calibration |
100ppm Isobutene or 20ppm Isobutene
|